2-4
2.3.1 General Installation Requirements (cont.)
FCC COMPLIANCE
The user is cautioned that any changes or modifications to Frymaster computers not expressly
approved by the party responsible for compliance could void the user’s authority to operate the
equipment. Frymaster computers have been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC rules. While these devices are verified as Class A
devices, they have been shown to meet the Class B limits. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to
radio communications. Operation of the equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense. If
necessary, the user should consult the dealer or an experienced radio and television technician for
additional suggestions.
The user may find the booklet “How to Identify and Resolve Radio-TV Interference Problems”
helpful. It is prepared by the Federal Communications Commission and is available from the U.S.
Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4.
2.3.2 Caster/Leg Installation
Depending upon the specific configuration ordered, your unit may have been shipped without
installed casters or legs. If casters or legs are installed, you may skip this section and proceed to
Section 2.4, Pre-Connection Preparations.
If your unit requires the installation of casters/legs, install them in accordance with the
instructions included in your accessory package.
2.4 Pre-Connection Preparations
DANGER
Do not connect this equipment to the gas supply before completing each step in this
section.
After the unit is positioned for use, ensure the following have been accomplished before connecting
the unit to the gas supply:
1. Adequate means must be provided to limit the movement of this equipment without depending
upon the gas line connections. If a flexible gas hose is used, a restraining cable must be
connected at all times when the equipment is in use.
2. The rethermalizer must be stabilized by installing restraining chains on units equipped with
casters or anchor straps on units equipped with legs. Follow the instructions shipped with the
casters/legs to properly install the chains or straps.
3. Level rethermalizers equipped with legs by screwing out the legs approximately 1 inch then